3 Technical data
12 F-125 Manual, Version B
3 Technical data
This section introduces the reader to the Recirculating Chiller and its specifications. It contains the
technical data, requirements and performance data.
3.1 Technical data
Technical data
Power consumption (max.) 2850 W
Supply voltage 230 VAC ± 10%
Fuse 16 AT
Output socket (max.) 2 A
Frequency 50/60 Hz
Environmental conditions
- Temperature
- Altitude
- Humidity
For indoor use only
5-40 °C
up to 2000 m
Maximum relative humidity 80% for temperatures up to 31 °C decreasing
linearly to 50% relative humidity at 40 °C
Display digital, resolution 0.1 °C
Overvoltage category II
Degree of protection IP20
Pollution degree 2
Instrument dimensions
W x H x D
990 x 580 x 650 mm
Weight 100 kg
Cooling power at 15 °C 2500 W
Refrigerant R134
Temperature range -10 °C ... +25 °C
Hysteresis ±1 °C
Tank volume 9 l
Hose connection 13.5 mm
Pump flowrate 14 l/min
Pump pressure 2.5 bar
3.2 Materials used
Materials used
Component Material designation Material code Hazardous substances
Stainless steel, powder-coated with
polyester-epoxide
Housing 1.4301
Polyester Lamina PES
Glass-fiber-reinforced epoxy resin Circuit board
Polyvinyl chloride Cable PVC
R134 Refrigerant 1,1,1,2-tetrafluoro-
ethane
Check MSDS